← All utilitiesHIL WORKBENCH / FREE BROWSER TOOLS
SIMITRO / ENGINEERING UTILITIES

Diagnostic debounce simulator

Explore counter-based and time-based qualification. Apply a sequence of pre-failed and pre-passed reports, then export the timeline.

Keep your usual setup ready.Save inputs on this browser. CSV files are not saved.

01 / INPUTS

Your result

ON YOUR DEVICE

Enter your inputs and calculate to see the result.

See when the fault qualifies.

The first report occurs at t = 0. Counter steps are applied immediately at each report, then clamped to the configured thresholds. Qualification persists between thresholds. In time mode, the first report of a new polarity starts its timer; repeated identical reports do not restart it. This model uses fixed steps and uninterrupted reporting; configure ECU-specific reset or jump behaviour separately.

Counter: clamp(previous + increment / −decrement) Time: elapsed since the first consecutive F or P report

Diagnostic event-manager reference ↗